ONLINE PAYMENT
TÜRKÇE  -   ENGLISH

AIR COOLED CHILLER

chiller-

COMPRESSOR
Hermetic ,semi-hermetic screw compressors are used at the devices.It has carter case heater and protective relays. Gas system is protected with the vibration receivers against to break.It runs quiet and safe many years.   COOLER (EVAPORATOR) Shell&Tube or plate type heat exchanger apparatus and the exterior of the cooler is insulated with appropriate insulation thickness.
CONDENSER According to the way you use the device ,air-cooled condenser, is demanded with cooper tubes and aluminum lamellae
FAN AND MOTOR In order to provide gas condensation air-cooled condenser in the cooling device, engine with a direct high-effiency axial fan is mounted on the device.
ELECTRICAL CONTROL PANEL To provide fully automatic operation of chiller equipment devices are placed on board a sufficient amount of the contactors, thermal, insurance, and are equipped with switches.
ELECTRONIC CONTROL SYSTEM Electronic control system is used in devices. In this way, water inlet and outlet temperatures, compressor and pump run-time and system malfunctions can be seen on the screen. In this way optimum efficiency operation of the device is provided.
COOLING CIRCUIT ELEMENTS For automatic and safe operation of the device ;(drier)-filter, sight glass, thermostatic expansion valve, solenoid valves, low-presostadı high pressure, water flow control valves and cooling valf are placed.  
COMPRESSORCompressors in the system from 1 to 6 single compressor has been designed according to the combined work.Device according to the capacity scroll type, semi-hermetic or screw type compressors are used in refrigeration.
EVAPORATOR Shell and tube or plate-type evaporator with heat exchanger system is produced.
CONDENSER Consist of condenser are copper tubes with corrugated aluminum lamellar. On the surrounding air fan circulates through the wings.Standard units run between 100C- 450C surrounding air temperature.
CONDENSER FAN AND MOTOR Condenser fan motor is electric two-speed circuit. Motor wings with aerodynamic wing-shaped is direct coupled. Fan enclosure has been placed.
POWER AND CONTROL SYSTEM Power and Control , control and protective devices are equipped with electrical power supply. It forwards pressure and temperature information on the display of micro –processor and fault status information to the user which makes it easier to use.



WATER COOLED CHILLER

chiller

COMPRESSOR Hermetic ,semi-hermetic screw compressors are used at the devices.It has carter case heater and protective relays. Gas system is protected with the vibration receivers against to break.It runs quiet and safe many years.   COOLER (EVAPORATOR) Shell&Tube or plate type heat exchanger apparatus and the exterior of the cooler is insulated with appropriate insulation thickness.
CONDENSER It is designed to make energy transfer from the water resources with the Shell & Tube or plate heat exchanger
ELECTRRICAL CONTROL PANEL To provide fully automatic operation of chiller equipment devices are placed on board a sufficient amount of the contactors, thermal, insurance, and are equipped with switches.
ELECTRONIC CONTROL SYSTEM Electronic control system is used in devices. In this way, water inlet and outlet temperatures, compressor and pump run-time and system malfunctions can be seen on the screen. In this way optimum efficiency operation of the device is provided.
COOLING CIRCUIT ELEMENTS For automatic and safe operation of the device ;(drier)-filter, sight glass, thermostatic expansion valve, solenoid valves, low-presostadı high pressure, water flow control valves and cooling valf are placed.  
COMPRESSOR Compressors in the system from 1 to 6 single compressor has been designed according to the combined work.Device according to the capacity scroll type, semi-hermetic or screw type compressors are used in refrigeration.
EVAPORATOR Shell and tube or plate-type evaporator with heat exchanger system is produced.
CONDENSER Consist of condenser are copper tubes with corrugated aluminum lamellar. On the surrounding air fan circulates through the wings.Standart üniteler 10 °C ~ 45 °C çevredeki hava sıcaklığı arasında çalışır. Standard units run between 100C- 450C surrounding air temperature
CONDENSER FAN AND MOTOR Condenser fan motor is electric two-speed circuit. Motor wings with aerodynamic wing-shaped is direct coupled. Fan enclosure has been placed.
POWER AND CONTROL SYSTEM Power and Control , control and protective devices are equipped with electrical power supply. It forwards pressure and temperature information on the display of micro –processor and fault status information to the user which makes it easier to use.